DDC
| 615 |
Tác giả CN
| Phạm, Thị Thu Hường |
Nhan đề
| Xây dựng quy trình phân tích đồng thời các chất bảo quản Propylparaben, Butylparaben, Triclosan trong mỹ phẩm bằng phương pháp HPLC/PDA / Phạm Thị Thu Hường, Đỗ Châu Minh Vĩnh Thọ |
Tóm tắt
| A reversed-phase HPLC coupled with PDA detector method was developed for simultaneous determination of proppylparaben, butylparaben and triclosan in commercial cosmetic products. The chromatography was performed by a Hitachi L-2000 HPLC system, with: Column - Phenomenex Gemini RP-C18 (150 x 4.6 mm; 5 µm); Mobile phase - Acetonitrile and water (in gradient mode); Flow rate - 1 mL/min; Detection UV (280 nm.). The method was validated by AOAC guideline to meet all the conventional requirements: system compatibility, selectivity, linearity range (R2 > 0,995), accuracy (recovery rate - 91 – 95 %) and precision (RSD < 2%), and high sensitivity (LOD: 0.034 – 0.04 ppm, LOQ: 0.11 – 0.13 ppm). To test for practical application, PrPB, BuPB and TCS in 20 cosmetic products, including suncream, acne treatment, burnt, freckles, skin whitening and regeneration collected in CanTho city. Of these samples, two exceeded the criteria and 15 products contained preservative ingredients other than those declared in the manufacturer’s trade labels. |
Thuật ngữ chủ đề
| Nghiên cứu kỹ thuật --Việt Nam |
Từ khóa tự do
| Butylparaben |
Từ khóa tự do
| Propylparaben |
Từ khóa tự do
| Triclosan |
Tác giả(bs) CN
| Đỗ Châu Minh Vĩnh Thọ |
Nguồn trích
| Tạp chí Dược học 2018tr. 43-47
Số: 11 |
|
000
| 00000nab#a2200000ui#4500 |
---|
001 | 18702 |
---|
002 | 9 |
---|
004 | 9B27F2F6-CD04-4BC4-998B-DAD184122E67 |
---|
005 | 201912061417 |
---|
008 | 081223s vm| vie |
---|
009 | 1 0 |
---|
039 | |y20191206141759|zthienvan |
---|
082 | |a615 |
---|
100 | |aPhạm, Thị Thu Hường |
---|
245 | |aXây dựng quy trình phân tích đồng thời các chất bảo quản Propylparaben, Butylparaben, Triclosan trong mỹ phẩm bằng phương pháp HPLC/PDA / |cPhạm Thị Thu Hường, Đỗ Châu Minh Vĩnh Thọ |
---|
520 | |a A reversed-phase HPLC coupled with PDA detector method was developed for simultaneous determination of proppylparaben, butylparaben and triclosan in commercial cosmetic products. The chromatography was performed by a Hitachi L-2000 HPLC system, with: Column - Phenomenex Gemini RP-C18 (150 x 4.6 mm; 5 µm); Mobile phase - Acetonitrile and water (in gradient mode); Flow rate - 1 mL/min; Detection UV (280 nm.). The method was validated by AOAC guideline to meet all the conventional requirements: system compatibility, selectivity, linearity range (R2 > 0,995), accuracy (recovery rate - 91 – 95 %) and precision (RSD < 2%), and high sensitivity (LOD: 0.034 – 0.04 ppm, LOQ: 0.11 – 0.13 ppm). To test for practical application, PrPB, BuPB and TCS in 20 cosmetic products, including suncream, acne treatment, burnt, freckles, skin whitening and regeneration collected in CanTho city. Of these samples, two exceeded the criteria and 15 products contained preservative ingredients other than those declared in the manufacturer’s trade labels. |
---|
650 | |aNghiên cứu kỹ thuật |zViệt Nam |
---|
653 | |aButylparaben |
---|
653 | |aPropylparaben |
---|
653 | |aTriclosan |
---|
700 | |aĐỗ Châu Minh Vĩnh Thọ |
---|
773 | |tTạp chí Dược học |d2018|gtr. 43-47|i11 |
---|
890 | |c1|a0|b0|d5 |
---|
| |
Không tìm thấy biểu ghi nào
|
|
|
|