thông tin biểu ghi
  • Bài trích
  • Ký hiệu PL/XG: 615
    Nhan đề: Xây dựng quy trình phân tích đồng thời các chất bảo quản Propylparaben, Butylparaben, Triclosan trong mỹ phẩm bằng phương pháp HPLC/PDA /

DDC 615
Tác giả CN Phạm, Thị Thu Hường
Nhan đề Xây dựng quy trình phân tích đồng thời các chất bảo quản Propylparaben, Butylparaben, Triclosan trong mỹ phẩm bằng phương pháp HPLC/PDA / Phạm Thị Thu Hường, Đỗ Châu Minh Vĩnh Thọ
Tóm tắt A reversed-phase HPLC coupled with PDA detector method was developed for simultaneous determination of proppylparaben, butylparaben and triclosan in commercial cosmetic products. The chromatography was performed by a Hitachi L-2000 HPLC system, with: Column - Phenomenex Gemini RP-C18 (150 x 4.6 mm; 5 µm); Mobile phase - Acetonitrile and water (in gradient mode); Flow rate - 1 mL/min; Detection UV (280 nm.). The method was validated by AOAC guideline to meet all the conventional requirements: system compatibility, selectivity, linearity range (R2 > 0,995), accuracy (recovery rate - 91 – 95 %) and precision (RSD < 2%), and high sensitivity (LOD: 0.034 – 0.04 ppm, LOQ: 0.11 – 0.13 ppm). To test for practical application, PrPB, BuPB and TCS in 20 cosmetic products, including suncream, acne treatment, burnt, freckles, skin whitening and regeneration collected in CanTho city. Of these samples, two exceeded the criteria and 15 products contained preservative ingredients other than those declared in the manufacturer’s trade labels.
Thuật ngữ chủ đề Nghiên cứu kỹ thuật --Việt Nam
Từ khóa tự do Butylparaben
Từ khóa tự do Propylparaben
Từ khóa tự do Triclosan
Tác giả(bs) CN Đỗ Châu Minh Vĩnh Thọ
Nguồn trích Tạp chí Dược học 2018tr. 43-47 Số: 11
000 00000nab#a2200000ui#4500
00118702
0029
0049B27F2F6-CD04-4BC4-998B-DAD184122E67
005201912061417
008081223s vm| vie
0091 0
039|y20191206141759|zthienvan
082 |a615
100 |aPhạm, Thị Thu Hường
245 |aXây dựng quy trình phân tích đồng thời các chất bảo quản Propylparaben, Butylparaben, Triclosan trong mỹ phẩm bằng phương pháp HPLC/PDA / |cPhạm Thị Thu Hường, Đỗ Châu Minh Vĩnh Thọ
520 |a A reversed-phase HPLC coupled with PDA detector method was developed for simultaneous determination of proppylparaben, butylparaben and triclosan in commercial cosmetic products. The chromatography was performed by a Hitachi L-2000 HPLC system, with: Column - Phenomenex Gemini RP-C18 (150 x 4.6 mm; 5 µm); Mobile phase - Acetonitrile and water (in gradient mode); Flow rate - 1 mL/min; Detection UV (280 nm.). The method was validated by AOAC guideline to meet all the conventional requirements: system compatibility, selectivity, linearity range (R2 > 0,995), accuracy (recovery rate - 91 – 95 %) and precision (RSD < 2%), and high sensitivity (LOD: 0.034 – 0.04 ppm, LOQ: 0.11 – 0.13 ppm). To test for practical application, PrPB, BuPB and TCS in 20 cosmetic products, including suncream, acne treatment, burnt, freckles, skin whitening and regeneration collected in CanTho city. Of these samples, two exceeded the criteria and 15 products contained preservative ingredients other than those declared in the manufacturer’s trade labels.
650 |aNghiên cứu kỹ thuật |zViệt Nam
653 |aButylparaben
653 |aPropylparaben
653 |aTriclosan
700 |aĐỗ Châu Minh Vĩnh Thọ
773 |tTạp chí Dược học |d2018|gtr. 43-47|i11
890|c1|a0|b0|d5
Không tìm thấy biểu ghi nào