DDC
| 615 |
Tác giả CN
| Trần, Thị Mỹ Dung |
Nhan đề
| Định lượng đồng thời Metronidazol và Spiramycin I trong huyết tương người bằng LC-MS/MS / Trần Thị Mỹ Dung, Bùi Mỹ Hạnh, Chương Ngọc Nãi, Nguyễn Đức Tuấn |
Tóm tắt
| An isocratic liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed for simultaneous assay of metronidazole (MET) and spiramycin I (SPIY I) in human plasma. The blank human plasma with MET, SPY I, and roxithromycin (ROX) added as was internal standards was treated by protein precipitation with acetonitrile. The analytes were chromatographed as follows: Column - Phenomenex NX C18 column (100 mm x 3.0 mm; 5.0 µm); Mobile phase - acetonitrile and ammonium formate 5 mM pH 7.4 (80:20, v/v); Flow rate - 0.4 mL/min.; Injection volume - 3 µL; Column temperature - 40oC; Detector – MS in positive ion electrospray ionization (ESI+) with multi-reaction monitoring (MRM) mode; m/z 171.75 → 128.10 for MET, 422.25 → 174.20 for SPY I, and 837.50 → 679.45 for ROX. Linearity covered the concentration range of 0.050-25.235 and 0.025-12.725 µg/ml for MET and SPY I, respectively. The intra- and inter-day accuracy and precisions (CV) were from 95.40 % to 106.39 % with CV value below 15.0 % for both MET and SPY I. The method showed appliable to determination of pharmacokinetic parameters of MET and SPY I in human plasma. |
Thuật ngữ chủ đề
| Nghiên cứu kỹ thuật--Việt Nam |
Từ khóa tự do
| Huyết tương người |
Từ khóa tự do
| Metronidazol |
Từ khóa tự do
| Spiramycin |
Tác giả(bs) CN
| Chương, Ngọc Nãi |
Tác giả(bs) CN
| Bùi, Mỹ Hạnh |
Nguồn trích
| Tạp chí Dược học 2019tr. 17-22
Số: 01 |
|
000
| 00000nab#a2200000ui#4500 |
---|
001 | 18567 |
---|
002 | 9 |
---|
004 | F24FC9FA-06D7-4795-952C-DFDED80E2F6E |
---|
005 | 201912040900 |
---|
008 | 081223s vm| vie |
---|
009 | 1 0 |
---|
039 | |y20191204090043|zthienvan |
---|
082 | |a615 |
---|
100 | |aTrần, Thị Mỹ Dung |
---|
245 | |aĐịnh lượng đồng thời Metronidazol và Spiramycin I trong huyết tương người bằng LC-MS/MS / |cTrần Thị Mỹ Dung, Bùi Mỹ Hạnh, Chương Ngọc Nãi, Nguyễn Đức Tuấn |
---|
520 | |aAn isocratic liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was developed for simultaneous assay of metronidazole (MET) and spiramycin I (SPIY I) in human plasma. The blank human plasma with MET, SPY I, and roxithromycin (ROX) added as was internal standards was treated by protein precipitation with acetonitrile. The analytes were chromatographed as follows: Column - Phenomenex NX C18 column (100 mm x 3.0 mm; 5.0 µm); Mobile phase - acetonitrile and ammonium formate 5 mM pH 7.4 (80:20, v/v); Flow rate - 0.4 mL/min.; Injection volume - 3 µL; Column temperature - 40oC; Detector – MS in positive ion electrospray ionization (ESI+) with multi-reaction monitoring (MRM) mode; m/z 171.75 → 128.10 for MET, 422.25 → 174.20 for SPY I, and 837.50 → 679.45 for ROX. Linearity covered the concentration range of 0.050-25.235 and 0.025-12.725 µg/ml for MET and SPY I, respectively. The intra- and inter-day accuracy and precisions (CV) were from 95.40 % to 106.39 % with CV value below 15.0 % for both MET and SPY I. The method showed appliable to determination of pharmacokinetic parameters of MET and SPY I in human plasma. |
---|
650 | |aNghiên cứu kỹ thuật|zViệt Nam |
---|
653 | |aHuyết tương người |
---|
653 | |aMetronidazol |
---|
653 | |aSpiramycin |
---|
700 | |aChương, Ngọc Nãi |
---|
700 | |aBùi, Mỹ Hạnh |
---|
773 | |tTạp chí Dược học |d2019|gtr. 17-22|i01 |
---|
890 | |c1|a0|b0|d12 |
---|
| |
Không tìm thấy biểu ghi nào
|
|
|
|